Reset All Units to Factory Default
Page 124 FlexWave Prism Element Management System 7.1 User Manual
©
2011 ADC Telecommunications, Inc ADCP-77-177 Issue 1July 2011
RESET ALL UNITS TO FACTORY DEFAULT
This procedure resets the Host and all connected Remote Units (PRU or URU) to
their factory default settings.
This procedure does not clear commanded Out of Service and Band Lockout
settings (see
Table on page 42).
1 Document all configuration data, as everything except user IDs and IP
configuration will have to be re-entered. To record the current configuration:
a Follow the procedures in “Viewing the All Report” on page 112 to access the
system configuration reports.
b Follow the procedures in “Downloading a Report” on page 113 to download
the system configuration reports to a hard drive.
2 In the System Tree, click on the Host icon.
3 In the Unit Menu bar, click Unit Configuration > Edit Properties, to open the Unit
Configuration > Edit Properties page.
4 Click Reset all units to factory defaults.
5 In the confirmation dialog, click OK.
The system configuration is cleared, and you are logged out of your current
EMS session.