User's Manual
Prism MIB Objects
Page 254 FlexWave Prism Element Management System 7.1 User Manual
©
2011 ADC Telecommunications, Inc ADCP-77-177 • Issue 1 • July 2011
Output Reference Clock
SNMP MIB:
fwuHstSysCardOutputRefClock
Description: System Card Reference clock. System Module supports only 10 MHz
and System Board II supports both 10 MHz and 30 MHz Clock output.
Values: 0 = Off
1 = 10 MHz clock
2 = 30 MHz clock
Default: 1 for Host
2 for IF Remote
Syntax: Integer
Access Level: Read-Write
RI Hardware Generation
SNMP MIB:
fwuHstSysCardRIHWGen
Description: Host System Card Hardware Generation
Values: 0 = First Generation
1 = Second Generation
Default: 1
Syntax: Integer
Access Level: Read Only
Remote Unit Parameters
Remote Parameters
Number
SNMP MIB:
fwuRmtNumber
Description: Number of the connected Remote Unit.
Values: See “Unit Identification” on page 43
Syntax: UnitId2
Access Level: Read Only
Name
SNMP MIB:
fwuRmtName
Description: User defined name of the Remote Unit.
Values: Alphanumeric Characters. Except as first character, the underscore
(_) character is allowed. Must be between 5 and 40 characters in
length, with no spaces.
Syntax: Display String
Access Level: Read-Write