User's Manual

Using an SNMP Interface
FlexWave Prism Element Management System 7.1 User Manual Page 253
ADCP-77-177 Issue 1July 2011 © 2011 ADC Telecommunications, Inc.
RI Serial Number
SNMP MIB:
fwuHstSysCardRISerialNumber
Description: Rmt Inventory Data - Serial Number
Syntax: Display String
Access Level: Read Only
RI Date Code
SNMP MIB:
fwuHstSysCardRIDateCode
Description: Rmt Inventory Data - Date Code
Syntax: Display String
Access Level: Read Only
RI HW Version
SNMP MIB:
fwuHstSysCardRIHWVer
Description: Rmt Inventory Data - Hardware Version
Syntax: Display String
Access Level: Read Only
10 MHz Reference Clock
SNMP MIB:
fwuHstSysCard10MhzRefClock
Description: System Card Reference clock
Values: 0-Internal
1-external ref clock
Default: 0
Syntax: Integer
Access Level: Read-Write
Clock Priority Level
SNMP MIB:
fwuHstSysCardCPLevel
Description: System card master clock priority level
Values: 1…14
Default: 14
Syntax: Integer32
Access Level: Read-Write