User's Manual

Using an SNMP Interface
FlexWave Prism Element Management System 7.1 User Manual Page 237
ADCP-77-177 Issue 1July 2011 © 2011 ADC Telecommunications, Inc.
Parameters in ADC-FLEXWAVE-URH-MIB
System-Level Parameters
System Date and Time
SNMP MIB:
fwuHstSystemDateAndTime
Description: The date and time settings on the system
Values: 1970-01-01,00:00:00 to 2037-12-31,23:59:59; see “System Date
and Time MIB Format” on page 234
Default: System time
Syntax: DateAndTime
Access Level: Octet String
System Alarm Acknowledge
SNMP MIB:
fwuSystemAlarmAck
Description: Acknowledges all or individual alarms
Values: 0 = Acknowledge all alarms
Greater then 0, Id of the alarm to be acknowledged
Syntax: Integer32
Access Level: Read-Write
System Alarm Level
SNMP MIB:
fwuAlarmLevel
Description: Alarm level of system
Syntax: AlarmType
Access Level: Read-Write
System Test On Power Up
SNMP MIB:
fwuPwrUpLinkTest
Description: System/Link Test on Power Up (Link Test)
Values: 1 = Enable
0 = Disable
Default: 0
Syntax: Unsigned32
Access Level: Read-Write