User's Manual
Using an SNMP Interface
FlexWave Prism Element Management System 7.1 User Manual Page 291
ADCP-77-177 • Issue 1 • July 2011 © 2011 ADC Telecommunications, Inc.
Do the following to enable or disable a trap through SNMP, in which the values
must be set in the sequence shown.
Do the following to enable or disable an alarm through SNMP, in which the values
must be set in the sequence shown.
1 Use fwuSystemTrapNodeAddress to set the unit address for the node, where 0
equals the Host, UnitId2 for DRU.
2 Use fwuSystemAlarmModuleNo to set the module number to be effected.
3 Use fwuSystemModuleAlarmcode to identify which alarm to enable/disable.
4 Use fwuSystemAlarmEnabled to change the value to enable/disable the alarm,
where:
• 1 = Enable
• 0 = Disable
Date and Time Stamps in Traps
Table 28 describes the date and time fields.
For Example:
Tuesday May 26, 1992 at 1:30:15 PM EDT
is displayed as:
1992-5-26,13:30:15.0,-4:0
Table 28. MIB Date and Time Stamp Fields
Field Octets Contents Range
1 1-2 year
(1)
0…65536
2 3 month 1…12
3 4 day 1…31
4 5 hour 0…23
5 6 minutes 0…59
6 7 seconds 0…59
7 8 deci-seconds 0…9
8 9 direction from UTC +' / '-'
9 10 hours from UTC
(2)
0…13
10 11 minutes from UTC 0…59
(1)
Value of year is in network-byte order
(2)