User's Manual

Configure Host Reverse Gain
Page 90 FlexWave Prism Element Management System 7.1 User Manual
©
2011 ADC Telecommunications, Inc ADCP-77-177 Issue 1July 2011
The Host Reverse Gain Settings table has the following columns.
DART Id—identifies the Host DART by the slot in which it is installed, which can
be from 1 through 8.
DART Name—identifies the DART by its user-defined name.
Reverse Gain Mode—whether the Reverse Gain Mode is Mode 1 (Noise Floor Matching)
or Mode 2 (Legacy Prism/URH).
Additive Gain (dB)—gain from the input to the Remote Unit to the output of the
Host DART. The range is 0 to 31 dB
Calculated Reverse System Gain (dB)—shows the end-to-end gain based on the
additive gain, gain mode, and number of Remote Units in the simulcast group.
Noise Floor (dBm/30kHz rbw)—shows the noise level for the configuration. The noise
floor is the measure of the signal created from the sum of all the noise sources.
Gain Mode—whether the Gain Mode is Normal or High.
Passband—type of passband provided by the DART.
Frequency (MHz)—passband frequency of the DART.