User's Manual
Configure Host Reverse Gain
Page 90 FlexWave Prism Element Management System 7.1 User Manual
©
2011 ADC Telecommunications, Inc ADCP-77-177 • Issue 1 • July 2011
The Host Reverse Gain Settings table has the following columns.
• DART Id—identifies the Host DART by the slot in which it is installed, which can
be from 1 through 8.
• DART Name—identifies the DART by its user-defined name.
• Reverse Gain Mode—whether the Reverse Gain Mode is Mode 1 (Noise Floor Matching)
or Mode 2 (Legacy Prism/URH).
• Additive Gain (dB)—gain from the input to the Remote Unit to the output of the
Host DART. The range is 0 to 31 dB
• Calculated Reverse System Gain (dB)—shows the end-to-end gain based on the
additive gain, gain mode, and number of Remote Units in the simulcast group.
• Noise Floor (dBm/30kHz rbw)—shows the noise level for the configuration. The noise
floor is the measure of the signal created from the sum of all the noise sources.
• Gain Mode—whether the Gain Mode is Normal or High.
• Passband—type of passband provided by the DART.
• Frequency (MHz)—passband frequency of the DART.