User's Manual
Initial FlexWave Prism System Setup
FlexWave Prism Element Management System 7.1 User Manual Page 87
ADCP-77-177 • Issue 1 • July 2011 © 2011 ADC Telecommunications, Inc.
f If you set the Power Level Mode to Max Hold, you can click Reset Max Hold to reset
the Max Hold values. The Host Forward Gain Settings table updates with the new
settings.
The Host Parameters table provides the following information:
• Peak Power (dBm)—shows the highest (peak) power level reached by the
Host DART
• Average Power (dBm)—shows the average power level reached by the Host
DART
• Minimum Power (dBm)—shows the minimum power level reached by the
Host DART
g Click Apply.
• Once the system executes the command, an Operation completed message
displays.
• The Host Forward Gain Settings table at the bottom of the page is updated
with the new settings.
h Repeat Step b on page 86 through Step g for each Host DART.
For information on the Host Forward Gain Settings table, see “Viewing the Host RF
Report” on page 108.