User's Manual

Initial FlexWave Prism System Setup
FlexWave Prism Element Management System 7.1 User Manual Page 83
ADCP-77-177 Issue 1July 2011 © 2011 ADC Telecommunications, Inc.
3 Click Apply. The Operation complete message displays, and the Remote Parameters
table clears so you can set the delay for another DART.
4 Repeat Step 2 through Step 3 for each DART.
Using the Linked DARTs Delay Table
The Linked DARTs Delay table provides the following information:
Host columns—identifies the Host in the link
DART Id—number of the Host slot in which the DART is installed
DART Name—user-defined name for the Host DART
Remote columns—identifies the Remote and its elements
Id—Unit ID of PRU/URU based upon layered address; see “Unit
Identification” on page 43
Name—user-defined label for the PRU/URU
DART Id—PRU/URU slot number in which the DART is installed
DART Name—user-defined name for the Remote DART
Forward Delay (s)—user requested FWD RF path delay in microseconds
Reverse Delay (s)—user requested REV RF path delay in microseconds
Common columns—configuration settings common to the Host and Remote(s)
Passband—type of passband provided by the DART.
Frequency (MHz)—passband frequency of the DART