User's Manual
Configure DART Links
Page 80 FlexWave Prism Element Management System 7.1 User Manual
©
2011 ADC Telecommunications, Inc ADCP-77-177 • Issue 1 • July 2011
GSM 1800 SuperDART
You can select a Start and Stop frequency for the passband in the frequency range
of 1805 MHz - 1880 Mhz.
PCS SuperDART
PCS SuperDARTs support the following subbands: A, B, C, D, E, F, G, H, A1, A2,
A3, B1, B2, B3, C1, C2, C3, C4, C5.
You can select any number of the subbands based on the limitations specified
below:
• The subband A cannot be chosen in conjunction with A1, A2, or A3.
• The subband B cannot be chosen in conjunction with B1, B2, or B3.
• The subband C cannot be chosen in conjunction with C1, C2, C3, C4, or C5.
• The subbands C1 and C2 cannot be chosen in conjunction with the subbands
C, C3, C4, or C5.
• The subbands C3, C4, and C5 cannot be chosen in conjunction with the
subbands C, C1, or C2.
• Up to two non-contiguous sets of subbands can be selected, and there must be
more than a 5 MHz gap between the bands.
The PCS SuperDART supports the following Start and Stop frequencies:
• The PCS RF SuperDART supports the selection of a Start and Stop frequency
for the passband as listed in
Table 19.
• The PCS RF SuperDART Start and Stop frequencies are in the range of
1930MHz - 2000MHz.
UMTS SuperDART
You can select a Start and Stop frequency for the passband in the frequency range
of 2110 MHz - 2170 MHz.