User's Manual

Configure DART Links
Page 80 FlexWave Prism Element Management System 7.1 User Manual
©
2011 ADC Telecommunications, Inc ADCP-77-177 Issue 1July 2011
GSM 1800 SuperDART
You can select a Start and Stop frequency for the passband in the frequency range
of 1805 MHz - 1880 Mhz.
PCS SuperDART
PCS SuperDARTs support the following subbands: A, B, C, D, E, F, G, H, A1, A2,
A3, B1, B2, B3, C1, C2, C3, C4, C5.
You can select any number of the subbands based on the limitations specified
below:
The subband A cannot be chosen in conjunction with A1, A2, or A3.
The subband B cannot be chosen in conjunction with B1, B2, or B3.
The subband C cannot be chosen in conjunction with C1, C2, C3, C4, or C5.
The subbands C1 and C2 cannot be chosen in conjunction with the subbands
C, C3, C4, or C5.
The subbands C3, C4, and C5 cannot be chosen in conjunction with the
subbands C, C1, or C2.
Up to two non-contiguous sets of subbands can be selected, and there must be
more than a 5 MHz gap between the bands.
The PCS SuperDART supports the following Start and Stop frequencies:
The PCS RF SuperDART supports the selection of a Start and Stop frequency
for the passband as listed in
Table 19.
The PCS RF SuperDART Start and Stop frequencies are in the range of
1930MHz - 2000MHz.
UMTS SuperDART
You can select a Start and Stop frequency for the passband in the frequency range
of 2110 MHz - 2170 MHz.