User's Manual
Initial FlexWave Prism System Setup
FlexWave Prism Element Management System 7.1 User Manual Page 79
ADCP-77-177 • Issue 1 • July 2011 © 2011 ADC Telecommunications, Inc.
SuperDART Models
The following sections describe the Prism SuperDART options.
700 Lower ABC SuperDART
The 700 Lower ABC SuperDART supports the following subbands: A, B, C.
Table 20 lists the passband selections for 700 Lower ABC SuperDARTs.
700 UpperC SuperDART
The 700 UpperC SuperDART supports the following passband: Upper C.
Table 21 lists the passband selections for 700 ABC SuperDARTs.
2100 AWS SuperDART
You can select any number of the subbands based on the limitations specified
below.
• The 2100 AWS SuperDART supports the following passbands: A, B, C, D, E, F.
• You can select up to two non-contiguous sets of subbands, but there must be
at least a 5 MHz gap between the bands.
• The Start and Stop frequencies are in the range of 2110MHz - 2155MHz.
EGSM 900 SuperDART
The EGSM 900 SuperDART supports the selection of a Start and Stop frequency
for the passband in the range of 925MHz - 960MHz.
Table 20. 700 Lower ABC SuperDART Passband Selection
Name Downlink Frequency
Range (MHz)
Uplink Frequency
Range (MHz)
A 728 - 734 698 - 704
B 734 - 740 704 - 710
C 740 - 746 710 - 716
Table 21. 700 UpperC SuperDART Passband Selection
Name Downlink Frequency
Range (MHz)
Uplink Frequency
Range (MHz)
UpperC 746 - 756 776 - 786