User's Manual
Initial FlexWave Prism System Setup
FlexWave Prism Element Management System 7.1 User Manual Page 75
ADCP-77-177 • Issue 1 • July 2011 © 2011 ADC Telecommunications, Inc.
Classic DART Models
The following sections describe the Prism Classic DART options.
800 APAC iDEN Classic DART
Table 13 lists the passband selections for 800 APAC iDEN Classic DARTs.
The 800 APAC iDEN DART also supports the SMR Low and SMR Low Wide
passbands. The 800 APAC iDEN Classic DART can be linked to a DART of the same
type and to an 800 SMR Classic DART (as long as the passband is either SMR Low
or SMR Low Wide).
Table 14 specifies supported linking between 800 SMR Classic
DARTs and 800 APAC iDEN Classic DARTs.
800 SMR Classic DART
Table 15 lists the passband selections for 800 SMR Classic DARTs.
Table 13. 800 APAC iDEN Classic DART Passband Selection
Name Downlink Frequency
Range (MHz)
Uplink Frequency
Range (MHz)
800 APAC iDEN 851 - 870 806 - 825
Table 14. Linking 800 SMR Classic DARTs and 800 APAC iDEN Classic DARTs
Host DART PRU/URU DART Passbands
800APAC 800APAC
low, wide,
apac
800APAC 800SMR low, wide
800SMR 800APAC low, wide
800SMR 800smr low, wide
Table 15. 800 SMR Classic DART Passband Selections
Name Downlink Frequency
Range (MHz)
Uplink Frequency
Range (MHz)
SMR Low 862 - 869 817 - 824
SMR Low Wide 851 - 869 806 - 824