User's Manual

Initial FlexWave Prism System Setup
FlexWave Prism Element Management System 7.1 User Manual Page 63
ADCP-77-177 Issue 1July 2011 © 2011 ADC Telecommunications, Inc.
SET NETWORK CONNECTIONS
1 To access the Set Network Connections page, in the System Menu bar, click System
Configuration > Set Network Connections.
2 Use the Networking Mode list to specify the mode under which IP addresses are
assigned to the Host Craft and Network ports. A single IP address defines the
system. This IP address is assigned to the Host either statically or by the DHCP
server on the NOC. No user setting/IP configuration is required for the
PRUs—IP addresses for connected PRUs are auto assigned.
DHCP—this mode indicates that the Host is a DHCP client and expects an IP
address to be assigned by an external DHCP server through a network
Ethernet connector. The Host Craft port has a DHCP server that can be used
to communicate with the Host directly, and from which you can access the
EMS.
Static—the default mode for the Craft Port, with a default IP address of
192.168.0.1. The Static Networking Mode allows you to set an IP address for
the Host and connected Remote Units that do not change unless you
manually change them.
3 If you change a port to Static Networking Mode, the address fields are enabled.
Otherwise you cannot change the network addresses. If you set a port to Static
Networking Mode, then do the following:
a In the IP Address box, enter a new IP address for the system, in the format
of xxx.xxx.xxx.xxx.
b In the Subnet Mask box, enter a new Subnet Mask address for the system, in
the format of xxx.xxx.xxx.xxx.
c In the Gateway box, enter a new Gateway address for the system, in the
format of xxx.xxx.xxx.xxx.
4 Click Apply. Once the system executes the command, an Operation completed
message displays.