User's Manual

Prism System Overview
FlexWave Prism Element Management System 7.1 User Manual Page 35
ADCP-77-177 Issue 1July 2011 © 2011 ADC Telecommunications, Inc.
Table 9. Remote Unit Technical Specifications
Parameter Specification Remarks
Enclosure dimensions Height x Width x Depth
Single-Band Inches
Centimeters
25.2  12.2  11.2
64 x 30.99 x 28.45
Dimension for width includes the
mounting brackets.
To have adequate clearance to open
the Remote chassis door, allow a
minimum of 7 inches at the left, right
and front of each Remote.
Dual-Band Inches
Centimeters
33.2  12.2  11.2
84.3 x 30.99 x 28.45
Tri-Band Inches
Centimeters
41.2  12.2  11.2
104.6 x 30.99 x 28.45
Quad-Band Inches
Centimeters
52.4  12.2  11.2
133.10 x 30.99 x 28.45
Mounting Wall, Pole, Inside Pole, and Vault
Weight Unpopulated Populated “Unpopulated” weight includes the
Solar shields, which are always
present.
“Populated” weight is the weight of the
chassis that has the SeRF Module and
RF Modules installed.
Single-Band Pounds
Kilograms
65 83
29 38
Dual-Band Pounds
Kilograms
81 117
37 53 kg
Tri-Band Pounds
Kilograms
97 151
44 68 kg
Quad-Band Pounds
Kilograms
116 188
53 85 kg
Outside Ambient
Temperature Rating -40° C to +50° C (-40º F to +122º F)
Storage Temperature -40° C to +70° C (-40º F to +158º F)
Humidity 10% to 90% non-condensing
Weather Resistance IP-65 Indoor or outdoor installation
Lightning Protection 20kA IEC 1000-45 8/30 ìs Waveform Provided by external lightning protector,
which is an accessory.
Cooling Fan, IP-55
Operating Voltage Range 10 - 28 Vdc
Operating Temperature Range -10 - 70°C (14°F - 158°F)
Storage Temperature Range -40 - 70°C (-40°F - 158°F)
Connectors
Network port RJ-45 female connector
AC power connector Sealed 3-pin Connection point for the AC power cord
Antenna cable connector 50 ohm N-Type (female) 50 ohms input/output impedance
Voltage input 100 to 240 VAC, 50 to 60 Hz Operating range 90 to 265 VAC
Current rating 15 AMPS
Encapsulation PBT Encapsulated Motor and Control PCB
Bearings Abec 3, double shielded, chrome ball bearings
Continuous Duty Life-Cycle 50,000 hours at 25°C (77°F)
Safety UL/C-UL File E137077, TUV