User's Manual

Prism System Overview
FlexWave Prism Element Management System 7.1 User Manual Page 13
ADCP-77-177 Issue 1July 2011 © 2011 ADC Telecommunications, Inc.
SeRF II Module LEDs
Ref # LED LED Color Description
1
SFP TX •OFF
GREEN
•RED
No Small Form-Factor Pluggable (SFP) present
SFP is present and the FPGA internal Phase-Locked Loop (PLL) is locked
SFP is present and the FPGA internal PLL is not locked
SFP RX •OFF
GREEN
•AMBER
•RED
No SFP present
Receiver has locked and framed to the incoming signal
Receiver has light, but is not locked to the incoming frequency or not framed
Receiver has no light
2 ALARM
GREEN No major alarm is present in the system
RED Initial bootup sequence, or a major alarm is present in the system
3 SYNTH
GREEN Locked
RED Unlocked
4 STATUS
GREEN No alarm for the SeRF II Module
RED Initial bootup sequence and should become GREEN within 1 minute; if RED after bootup, a
Major alarm exists for the SeRF II Module
5 POWER
GREEN Power OK and operating properly
RED Power supply out of tolerance
OFF No power present