Figure 8. Connecting Antenna Cable to Antenna Port
4.5 Ground Wire Installation
A socket head capscrew with washer is provided on the underside of the cabinet for attaching a
#6 copper grounding wire to the unit. A #6 AWG copper wire terminated with a ring terminal
should be used to connect the unit to an approved grounding source. Avoid sharp bends in the
ground wire. Use the following procedure to install the grounding wire:
1. Locate a #6 AWG (4 mm) copper grounding wire long enough to reach an approved earth
ground.
2. Locate the grounding point provided on the underside of the unit as shown in Figure 9.
3. Remove the socket-head capscrew and flat washer from the unit using a #6 metric key or a
7/32-inch hex key wrench.
4. Secure the ring terminal end of the grounding wire to the unit using the screw and washer
removed in Step 3. Tighten securely.
Caution: For proper and safe equipment operation, an approved earth ground connection must
be provided. The recommended minimum wire size is #6 AWG copper wire.
BOTTOM VIEW
ANTENNA PORT
(N-TYPE FEMALE)
22443-A
ANTENNA
CABLE
TO
EARTH
GROUND
LIGHTNING
SURGE SUPPRESSOR
(ACCESSORY)
SURGE PORT