ADCP-75-347 • Issue 1 • 04/2008
Page 11
© 2008, ADC Telecommunications, Inc.
4. Slide the connector nut up to the port until it engages the connector locking mechanism.
5. Tighten the connector nut in a clockwise direction (if necessary, use a wrench or pliers to
grip the connector nut) until it snaps past the detent position and locks into place.
4.3 Quad Fiber Cable Installation
URH Remote Unit is shipped a 10 meter of environmentally hardened cable with 1 meter of
exposed, un-terminated single-mode 900µm optical fiber sufficient for splicing in an Outside
Plant (OSP) splice tray. The fiber cable connector is a BX5 4-port fiber connector.
Use the following procedure to install the fiber cables:
1. Remove the dust cap from the BX5 connectors located at the bottom of the RU as shown
in Figure 6.
2. Remove the dust cap from the fiber cable BX5 connector (FIBER 1).
3. Align the plug end of the BX5 cable connector with the BX5 port receptacle and then
insert the cable plug into the port receptacle.
4. Slide the strain relief boot over the connector.
Figure 6. Fiber Cable Installation
5. Route the fiber cable from the underside of the RU to the OSP box.
Note: It may be necessary to apply 30 to 50 lbs/force-inches (3.4 to 5.6 Nm) of torque to
the connector nut in order to turn it past the detent position.
BX5 PORT
RECEPTACLE
BX5 CABLE
CONNECTOR
22439-A