User's Manual

ADCP-75-347 • Issue 1 • 04/2008
Page 7
© 2008, ADC Telecommunications, Inc.
2 UNPACKING AND INSPECTION
This section provides instructions for opening the shipping boxes, verifying that all parts have
been received, and verifying that no shipping damage has occurred. The basic RU includes the
following items:
•Remote Unit
Solar Shields
Table 2. FlexWave URH Remote Unit User Interface
USER INTERFACE
DESIGNATION
DEVICE
FUNCTIONAL DESCRIPTION
FIBER 1
BX5 Duplex Female sin-
gle-mode non-angled UPC
fiber (>50 dB return loss *)
Connection point for the OSP cable from the Host
unit.
FIBER 2
BX5 Duplex Female sin-
gle-mode non-angled UPC
fiber (>50 dB return loss *)
Spare
ANT 1 TXO/RXO N-Type 50-Ohm female
RF coaxial connector
Left door connection point for transmit RF power
and primary receive to/from the antenna.
ANT 1 RX1 N-Type 50-Ohm female
RF coaxial connector
Left door connection point for diversity receive
for RF power from the antenna.
ANT 2 TXO/RXO N-Type 50-Ohm female
RF coaxial connector
Right door connection point for transmit RF
power and primary receive to/from the antenna.
ANT 2 RX1 N-Type 50-Ohm female
RF coaxial connector
Right door connection point for diversity receive
for RF power from the antenna.
ANT 3 TXO/RXO N-Type 50-Ohm female
RF coaxial connector
Front door connection point for transmit RF
power and primary receive to/from the antenna.
ANT 3 RX1 N-Type 50-Ohm female
RF coaxial connector
Front door connection point for diversity receive
for RF power from the antenna.
Network Sealed RJ-45 female con-
nector
Connection point for communication with the
entire connected network: host, remote, and ENET
connected devices at the remote.
Status Red LED
(off, Flashing red)
Indicates if RU is powered and normal (off) or if a
major fault is detected (flashing red).
100/240 VAC
50–60 HZ
15 AMPS
Sealed 3-wire AC power
connector
Connection point for the AC power cord.
Socket head screw Connection point for grounding unit.
* – ADC connector specification
Caution:
Cooling fins on the Remote Unit may have sharp corners and edges, to prevent cuts and
scrapes always wear gloves and appropriate protective clothing when handling the Remote Unit.