Page 190 FlexWave Prism Host, Remote and EMS 5.1 System Reference
© 2009 ADC Telecommunications, Inc ADCP-77-073 • Issue 2 • 11/2009
11 Remove the dust cap from the RJ-45 connector located at the bottom of the
Remote as shown below.
22 Route the network cable from the network connection to the underside of the
Remote.
33 Align the plug end of the RJ-45 cable connector with the RJ-45 port receptacle and
then insert the cable plug into the port receptacle.
44 Slide the connector nut up to the port until it engages the connector locking
mechanism.
55 Tighten the connector nut in a clockwise direction (if necessary, use a wrench or
pliers to grip the connector nut) until it snaps past the indented position and
locks into place. It may be necessary to apply 30 to 50 in-lbs (3.4 to 5.6 Nm) of
torque to the connector nut in order to turn it past the indented position.
It may be necessary to apply 30 to 50 lbs/force- inches (3.4 to 5.6 Nm) of torque to the
connector nut
in order to turn it past the indented position.
NETWORK
AUX.
MOD A
RX1
MOD A
TX0/RX0
FIBER 1
FIBER 2
MOD B
TX0/RX0
MOD B
RX1
MOD C
TX0/RX0
MOD D
TX0/RX0
MOD C
RX1
MOD D
RX1
POWER
100-240 VAC
50-60 Hz
16 AMPS
RJ-45 Network
Connector port
Network cable
Connector nut
RJ-45 plug
Bottom View
77073-010