7.2 SETTING AUTO REFRESH
Auto Refresh is intended for use after the Prism system has been configured during
initial setup and you want to monitor system performance without having to trigger
manual page refreshes.
11 In the EMS Menu bar, click
Configuration.
The
General Configuration
window opens.
22 In the
Auto Refresh
list, select
yes
to set the EMS pages to auto refresh.
33 In the
Auto Refresh Time
box, enter the number of seconds (
1
-
1800
) between EMS
auto refreshes.
44 Click
Apply
.
Only a user logged in under the admin or a Network Manager account can change Prism
settings through
the EMS.
Do not set Auto Refresh until after the initial Prism system setup described in “Initial
Prism System Setup” on page 143. If you apply Auto
Refresh before initial system setup,
entered configurations can be lost.