User Manual Part 2

Using the EMS to Manage a Prism System
Page 178 FlexWave Prism Host, Remote and EMS 5.1 System Reference
© 2009 ADC Telecommunications, Inc ADCP-77-073 Issue 211/2009
7.1 DISPLAYING THE SYSTEM VIEW
In the Function Explorer Tree, click on
System View
to open the system view, which is
labeled as the
Alarm Summary
, in the EMS View Frame.
The
Alarm Summary
provides a top-level view of the Prism system, which identifies the
Host and all Remotes known to the EMS by their IP addresses and provides a
summary alarm status indicator for each unit.
Host Unit Name
—name entered by user or
Unknown_HostName
if no name has been
entered. Current summary alarm state of Host is indicated by status indicator in
same row.
Alarm Summary
indicator—indicates if the state of the unit:
Green indicates a Normal state
Yellow indicates that a Minor alarm is active, and is the highest-level active
alarm
Red indicates that a Major alarm is active.
Remote Unit Name
—name entered by user or
Unknown_RmtName
if no name has
been entered. Summary alarm state is indicated by status indicator in same row.
IP Address
(Host/Remote)—IP Address of the Host/Remote. If logged into a Remote
that is not connected to a Host, the Host IP Address will appear as
NOT_CONNECTED
, and the Remote IP Address will appear as
0.0.0.0
if the remote
is setup for DHCP. If a static IP address has been assigned to the Remote, the
actual IP address for the Remote will display when the Host is not connected.