User Manual Part 2
(Optional) Configuring Multi-Host Systems for Manual Mode
FlexWave Prism Host, Remote and EMS 5.1 System Reference Page 175
ADCP-77-073 • Issue 2 • 11/2009 © 2009 ADC Telecommunications, Inc.
•• Remotes are set to Cellular A"/A Band which has 8 usec of system delay.
The delay ranges will therefore be:
– Remote 1 delay (48-136)
– Remote 2 delay (88-176)
The system calculates these delay values—this is a typical example based
on the fiber lengths provided. You select a delay value that’s within the
range calculated by the system.
Set the delays to the same values for all nodes in the network in order to:
•• Optimize simulcast
•• Make BTS datafill changes simple (same delay offsets for all nodes)
•• Simplify E-911 integration (same delay offsets for all nodes)
Delays cannot be shortened; they can only be lengthened. The
recommended approach is to normalize all Remotes to the longer
minimum delay. In this example the delay would therefore have to be 88
usec.
ii In the
DART Reverse Delay
box, set in microseconds the actual delay that will be
applied to the RF reverse path signal. The actual delay of the RF path will be
within 1 usec. For E-911 TDOA applications, the reverse path delay must be
measured to achieve the +/- 50 nsec delay accuracy specified for DAS
networks. The FWD and REV delay values are usually the same because the
fiber path between the two is typically the same.
133 Click
Apply
.