User Manual Part 2
Installing the Remote Unit
Page 96 FlexWave Prism Host, Remote and EMS 5.1 System Reference
© 2009 ADC Telecommunications, Inc ADCP-77-073 • Issue 2 • 11/2009
4.2 REMOTE MOUNTING PLANS
The FlexWave Prism Remote Unit has a low profile design that requires minimal real
estate for installation. The basic dimensions and weights of the Remote are listed in
Table 4-2.
The Prism Remote should be mounted on a utility pole, mast, or on a flat surface. A
mounting kit is available for each unit. Installation consists of securing the bracket
to the mounting surface (wood, concrete, or steel) and then hanging the unit from the
bracket. The Remote should only be mounted in a restricted access location.
Detailed instructions for mounting the FlexWave Prism Remote are in the Remote Unit
Mounting Kit Installation Instructions (ADCP-77-077).
Table 4-2. Remote Dimensions
Remote Configuration Depth Width Height Weight of Fully
Populated Units
Single- Band
10.51
"
12.15
"
22.50" <
65 lbs
Double Band
10.51
"
12.15
"
30.50" <
96 lbs
Triple Band
10.51
"
12.15
"
38.46" <
127 lbs
Quad- Band
10.51
"
12.15
"
49.60" <1
65 lbs