User Manual Part 2
Installing the Remote Unit
Page 128 FlexWave Prism Host, Remote and EMS 5.1 System Reference
© 2009 ADC Telecommunications, Inc ADCP-77-073 • Issue 2 • 11/2009
444 Remove the dust cap from the AC power port located on the bottom of the Remote
as shown below.
455 Connect the power cable connector to the AC power port.
466 Tighten coupling nut until the green band at the top of the connector body is
visible.
While trying to connect the AC power cable to the Remote AC power port, it is possible
for the line t
erminal on the cable connector to contact the ground pin on the power port.
If the AC cable is energi
zed, this will result in a direct short to ground for the AC power.
To avoid possible personal injury
and equipment damage, always turn the AC power off
before connecting the AC power cable to the AC po
wer port.
NETWORK
AUX.
MOD A
RX1
MOD A
TX0/RX0
FIBER 1
FIBER 2
MOD B
TX0/RX0
MOD B
RX1
MOD C
TX0/RX0
MOD D
TX0/RX0
MOD C
RX1
MOD D
RX1
POWER
100-240 VAC
50-60 Hz
16 AMPS
77073-015
Bottom View
Power
cable
Green band will be
visible when coupling —
Nut is tightened