4.4.4 Ground Wire Installation
122 Locate a #6 AWG (4 mm) copper grounding wire long enough to reach an approved
earth ground.
133 Use a socket wrench with a 3/8-inch deep socket to remove the two 10-32 Keps
Nuts from the Remote’s Dual-Ground connector.
144 Secure the ring terminal end of the grounding wire to the ground studs on the unit
using the two 10-32 Keps Nuts removed in Step 13, and then torque the nuts to
18 in-lbs ± 1 in-lb.
155 Route the free end of the grounding wire to an approved earth ground source.
166 Cut the ground wire to length and connect it to the earth ground source as
specified by local code or practice.
Avoid sharp bends in the ground wire.
For proper and safe equipment operation, use a #6 copper wire terminated with the
provided ring termi
nal to link the Remote to an earth- ground source.
Partial Bottom View
Dual-Ground Connector
77073-014
To Earth Ground
Ground Wire
10-32 Keps Nut
Ring Terminal