Installing the Remote Unit
Page 114 FlexWave Prism Host, Remote and EMS 5.1 System Reference
© 2009 ADC Telecommunications, Inc ADCP-77-073 • Issue 2 • 11/2009
8 Follow these rules when connecting the RF Module cables:
• At each RF Module shelf, the Power (PWR) cable and two high-speed-data
cables will always be provided.
• If you are installing a module into a Non-Diversity Chassis, only one RF
cable labeled MOD N TX0/RX0 will be populated.
• High-speed data cables labeled PRIM and DIV should always either be
connected or strain relieved to adjacent cables. This protects against the
cable getting caught in the chassis door.
• If you order a Non-Diversity RF Module and are installing it in a Diversity
chassis, connect it as if it was being installed into a Non-Diversity chassis.
• Connect both high-speed data cables (PRIM and DIV) and the RF TX0/RX0
cable.
• Adhere to a minimum bend radius of 1" for all RF cables from the integrated
cable guide to the module.
• Maintain adequate strain relief distances from connection points to the
module.
• When installing dual-slot RF modules:
– The upper RF Module shelf will either not be present (factory installed
module) or will be removed prior to installation (field installed module).
– For dual-slot modules, only the RF cable labeled MOD N TX0/RX0 on the
lower module slot will be connected to the module connector TX0/RX0.
–The MOD N RX1 cable should be secured to the cable bundle using the
provided cable tie.
– Ensure that the MOD N RX1 cable and connector are secured so that they
will not be pinched or prevent the Remote door from closing.
– The Power (PWR) cable and two high-speed-data cables of the upper RF
Module slot will not be used. Connect the RF cable labeled MOD N RX1 to
the connector labeled N/C on the upper half of the double-slot module.
Use one of the provided cable ties to secure the MOD N TX0/RX0 RF cable,
both high-speed data cables and the Power (PWR) cable to the RF cable
labeled MOD N RX1, ensuring that the cable bundle will not be pinched or
prevent the Remote door from closing.