User Manual Part 2
Using the EMS to Manage a Prism System
Page 192 FlexWave Prism Host, Remote and EMS 5.1 System Reference
© 2009 ADC Telecommunications, Inc ADCP-77-073 • Issue 2 • 11/2009
7.4.2.2 Accessing the EMS Through the Remote Craft Port
You can use the Craft port on the SeRF Module to access the FlexWave EMS to view
system configuration and alarms. For example, if there is a problem communicating
with the Remote and you have determined that fiber is not the issue, connecting to
the Craft port helps you obtain beneficial troubleshooting information.
11 Verify that your PC network interface is configured for DHCP.
22 If you have a wireless network interface, disable it. Otherwise an IP conflict may
result if the wireless network resides in the same IP subnet as the Craft port.
33 Open the Prism door.
44 Remove the dust cap from the Craft port located on the SeRF Module.
When you access the EMS through the Remote Craft port, the EMS GUI shows only the
Remote in its Funct
ion Explorer Tree. You cannot configure any system components or
clear alarms.
77073-025
RJ-45 Craft port
RJ-45
Connector