Installing the Host Unit
Page 82 FlexWave Prism Host, Remote and EMS 5.1 System Reference
© 2009 ADC Telecommunications, Inc ADCP-77-073 • Issue 2 • 11/2009
Use the following procedure to install the alarm wiring and connect it to the Host:
533 Obtain the required length of category 3 or 5 cable.
544 Route the cable between the Host System card and the alarm system (if not
already routed) and then cut to the required length. Allow sufficient slack for
dressing and organizing the cable at the Host.
555 Strip back the outer cable sheath and insulation to expose the wires at both ends
of the cable and strip back 0.2 inches (5 mm) of insulation from each wire.
566 Connect the Major alarm wire pair to the MAJOR COM/NC or MAJOR COM/NO
terminals (whichever is required by the alarm system) on the Host System card
alarm terminal connector (supplied with Host System card).