User Manual Part 1
Install the Host
FlexWave Prism Host, Remote and EMS 5.1 System Reference Page 81
ADCP-77-073 • Issue 2 • 11/2009 © 2009 ADC Telecommunications, Inc.
3.3.10 System Alarm Connections
The alarm interface between the Host and an alarm system is supported by
twelve-terminal plug (with screw-type terminals) that connects to a receptacle
mounted on the Host System card front panel. The terminal plug provides
connections to normally open (NO) and normally closed (NC) dry type alarm contacts
for both major and minor alarms. A category 3 or 5 cable is typically used to connect
the Host System card to the alarm system.
Table 3-1. System Card Alarm Pin Designations
PI
N
Description
Required
Wires
NC NO
1 Host Minor Normally Closed X
2 Host Minor Common X X
3 Host Minor Normally Open X
4 Host Major Normally Closed X
5 Host Major Common X X
6 Host Major Normally Open X
7 Remote Minor Normally
Closed
X
8 Remote Minor Common X X
9 Remote Minor Normally
Open
X
10 Remote Major Normally
Closed
X
11 Remote Major Common X X
12 Remote Major Normally Open X