Page 74 FlexWave Prism Host, Remote and EMS 5.1 System Reference
© 2009 ADC Telecommunications, Inc ADCP-77-073 • Issue 2 • 11/2009
3.3.7.1 Optical Connections Without WDM System
Use the following procedure to connect the optical fibers when a WDM is not
installed.
255 Obtain two patch cords that are of sufficient length to reach from the Host to the
fiber distribution panel.
266 Designate one of the patch cords as the forward path link and the other as the
reverse path link and attach an identification label or tag next to the connector.
277 Remove the dust caps from the Host SeRF SFP optical ports and from the patch
cord connectors that will be connected to the SeRF SFP optical ports.
288 Clean each patch cord connector following the patch cord supplier’s
recommendations.
299 Connect the LC attenuator to the patch cord.
300 Plug the FWD and REV path patch cords to the corresponding transmit (FWD) and
receive (REV) connections depending on the remote node SFP position.
Improper handling can damage fiber optic cables. Do not bend fiber optic cable more
sharply than the
minimum recommended bend radius specified by the cable
manufacturer. Do not apply more pulling force
to the cable than specified.