User Manual Part 1
Install the Host
FlexWave Prism Host, Remote and EMS 5.1 System Reference Page 69
ADCP-77-073 • Issue 2 • 11/2009 © 2009 ADC Telecommunications, Inc.
3.3.4 Chassis Ground Connection
A stud is provided on the rear side of the chassis for connecting a grounding wire to
the chassis. Use the following procedure to connect the grounding wire to the chassis
and to route the grounding wire to an approved earth ground source.
122 Obtain a length of #18 AWG (1.00 mm) insulated stranded copper wire for use as
a chassis grounding wire.
133 Terminate one end of the wire with a ring terminal.
144 Locate the chassis-ground stud at the rear of the Host chassis as shown in in the
following graphic, and then attach the ring end of the wire to the chassis ground
stud.
155 Route the free end of the chassis grounding wire to an approved (per local code
or practice) earth ground source.
166 Cut the chassis grounding wire to length and connect it to the approved ground
source as required by local code or practice.
Maintain reliable grounding. Pay particular attention to ground source connections.
Rear of Host Chassis
Star
washer
Hex
nut
Ground
wire
77073-062
Star
washer
Chassis-
ground
stud