2.5 PRISM SYSTEM SPECIFICATIONS
2.5.1 Host Unit Specifications
Parameter Specification Remarks
Dimensions (HuWuD) 5.17 u17.26u9.5 inches
(131.3 u 438.4 u 241.3 mm)
Dimension for width does not
include the mounting brackets
which can be installed for either
19- or 23-inch racks.
Mounting 19- or 23-inch rack EIA or WECO
Weight 20 lbs. (9.1 kg)
Weather resistance Indoor installation only Environmentally controlled
outdoor
cabinet.
Operating temperature 0º to 55º C (32º to 131º F)
Storage temperature –40º to 70º C (–40º to 158ºF)
Humidity 10% to 90% No condensation
Optical ports SFP transceivers LC (UPC)
Optical power levels Launch power
Minimum: -2 dBm
Maximum: 3 dBm
Receive power
Minimum: -27 dBm
Maximum: -9 dBm
Transceivers Wavelengths:
• Host transmits a 1550 nm
signal
• Remote transmits a 1310 nm
signal
• Host and Remote can receive
either a 1550 or 1310 nm
signal
For information on transceiver
transmissions with a CWDM, see
the ADC FlexWave Prism Coarse
Wavelength Division Multiplexer
User Manual (ADCP-75-353).
External alarm connector Screw-type terminals NO, COM, and NC relay contacts
DC Power ±20 – ±60 Vdc
Power consumption Maximum: 320 Watts
Nominal: 202 Watts
Current rating
4.2 Amps
8.4 Amps
At –48Vdc
At +24Vdc
RF coaxial cable connectors 50 ohm QMA – type (female) 50 ohms input/output
impedance
Network and Craft connectors RJ–45 jack