User Manual Part 1

FlexWave Prism System
Page 14 FlexWave Prism Host, Remote and EMS 5.1 System Reference
© 2009 ADC Telecommunications, Inc ADCP-77-073 Issue 211/2009
Figure 1-6 shows the possible slot assignments for Single and Dual SuperDARTs, and
where slot-divider bars are located.
A Classic DART or Single SuperDART can be installed in each of the eight slots in
the Host.
Dual SuperDARTs occupy two slots (1/3, 2/4, 5/7 or 6/8).
Dual SuperDARTs cannot occupy slot combinations 3/5 or 4/6.
Any combination of DARTs may be installed.
Figure 1-6. DART Slot Assignments in Host Chassis
Figure 1-7 shows a Host that is fully loaded with Dual SuperDART cards.
Figure 1-7. Host with Dual SuperDARTs
SeRF Card
System Card
Power Supply
Single-Slot DART
in Slot 1
Single-Slot DART
in Slot 3
Single-Slot DART
in Slot 2
Single-Slot DART
in Slot 4
Single-Slot DART
in Slot 7
Single-Slot DART
in Slot 5
Single-Slot DART
in Slot 8
Single-Slot DART
in Slot 6
Fan Assembly
Divider bars between
Slots 1 and 3
and Slots 2 and 4
Divider bars between
Slots 5 and 7
and Slots 6 and 8
SeRF Card
System Card
Power Supply
Fan Assembly
77073-077
Dual-Slot DART
in Slots 1 and 3
Dual-Slot DART
in Slots 2 and 4
Single-Slot DART
in Slot 7
Single-Slot DART
in Slot 5
Single-Slot DART
in Slot 8
Single-Slot DART
in Slot 6
Divider bars between
Slots 1 and 3 and
Slots 2 and 4 removed
to accommodate
Dual-Slot DARTs
SeRF Card
System Card
Power Supply
Fan Assembly
Dual SuperDART
in Slots 1 and 3
Dual SuperDART
in Slots 2 And 4
Dual SuperDART
in Slots 5 And 7
Dual SuperDART
in Slots 6 And 8
77073-078