User Manual Part 1

Installing the Host Unit
Page 86 FlexWave Prism Host, Remote and EMS 5.1 System Reference
© 2009 ADC Telecommunications, Inc ADCP-77-073 Issue 211/2009
700 Turn the DC power switch to its ON position.
Under normal operating conditions, the Host responds as follows:
aa Immediately—PWR LED turns Green
bb Within 6 to 7 seconds—ALARM, SYNTH, and SW FLT LEDs turn Red
cc Approximately 10 seconds—ALARM LED goes out
dd Approximately 30 seconds—SYNTH LED goes out
ee Approximately 1 minute—SW FLT LED goes out
ff Approximately 2.5 minutes—Craft port assigns IP Address to Laptop,
making Telnet management through the Craft port available
gg Approximately 3 minutes—SYNTH LED turns Green
hh Approximately 5 minutes—Element Management System (EMS) available on
Craft port (1 - 2 minutes after SYNTH LED turns Green)
Refer to the following graphic for location of the LEDs referenced above.
ALARM LED
SYNTH LED
SW FLT LED
DC power switch Power LED
77073-074
Craft port