User's Manual
Link the Host and Remote DARTs.
FlexWave Prism Host, Remote and EMS 5.1 System Reference Page 163
ADCP-77-073 • Issue 2 • 11/2009 © 2009 ADC Telecommunications, Inc.
The
Configuration Details
 table has the following columns:
•
Host DART Id
—Slot number of slot occupied by the Host DART card. The Host 
has eight slots numbered from 1 to 8, read from top to bottom. If the Host 
DART is a 12-Timeslot DART, then only the first of the two slots it occupies 
will be shown (for example, if the Host 12-Timeslot DART occupies slots 1 and 
3, only slot 1 will be shown).
•
Host  DART  SFP  Id
—Port number of physical optical port where Host-Remote 
optical fiber is connected on the Host.
•
Host  DART  Band
—Frequency band of the Host DART. This field is not 
configurable and reports the DART type (such as, cellular, pcs, and so forth).
•
Host DART Pass Band
—Passband assigned to the specified Host DART.
•
Host DART Status
—System entered status of Host DART card. This will be active, 
standby, or not in service
•
Remote  DART  Id
—Number (1-8) indicating the physical location where this 
DART card is mounted in the Remote; see “RF Groups in the Remote and the 
EMS GUI” on page 160) for an explanation of how the Remote DARTs are 
numbered.
•
Remote DART SFP Id
—Shows the available Remote SFPs that can be used to link 
the DARTs. 
1
 is shown in this example, so the Remote has fibers connected to 
this Host using Remote SFP 1. If there are two or more sets of SFPs connected 
between the same Host DART and Remote DART, this field will contain a value 
such as 
2/3
 or 
2/3/4
 where each one-digit number represents one Remote 
optical port where an SFP is connected for this Host/Remote pair. Each set of 
one Host SFP and one Remote SFP supports two optical fibers (RX and TX), each 
with a capacity of 12 TDM timeslots
•
Remote DART Status
—System entered status of Remote DART card, which can 
be
active
 or 
unlink
•
Decommission
 button—used to clean out settings and information for 
hardware that has been removed.
•
LPA  Reset
 button—When clicked, causes the LPA to reset as described in 
“Restarting an LPA” on page 236.
366 To link the Host DART to the Remote DART for this pass band, click in the radio 
button next to Host DART Id (ID 
1
 in this example).