User's Manual
Initial Prism System Setup
Page 148 FlexWave Prism Host, Remote and EMS 5.1 System Reference
© 2009 ADC Telecommunications, Inc ADCP-77-073 • Issue 2 • 11/2009
111 Click 
Apply
. The new 
Host Name
 displays in the Function Explorer Tree and the 
Host 
Summary
 view as part of the view title and in the 
Host Name
 box.
122 In the 
10  MHz  Reference  Clock
 list, select 
internal
 (default) or 
external
. The SeRF 
board on each Host and Remote contains the master clock for that unit. At the 
Remote, the reference is a clock derived from the Host clock. The 
10 MHz Reference 
Clock external
 setting allows you to frequency lock the master clock to an external 
10 MHz reference.
You may need to click in the Function Explorer Tree frame and then click Refresh before 
the new name 
appears.
When using the 10 MHz external reference clock, the signal must be connected to the 
Host before enabl
ing the clock in the software. If an external 10MHz reference clock is 
selected for operation, but is
 not present or outside of the frequency range of 10MHz 
+ /-  5ppm, communication between the Host and 
Remote over the optical fiber will fail.