Page 242 FlexWave Prism Host, Remote and EMS 5.1 System Reference
© 2009 ADC Telecommunications, Inc ADCP-77-073 • Issue 2 • 11/2009
44 If any status indicator in the 
Major Alarms
 or 
Minor Alarms
 table is red or yellow, 
refer to the following list:
•
Remote  Capacity
—Number of slots for RF Modules in the remote. Each RF 
Module comprises up to two Classic DARTS or Single SuperDARTs or one Dual 
SuperDART.
•
Remote  Temperature
 field—Currently detected internal temperature of the 
Remote (measured near the SeRF board).
•
Host  Lost Fault
 status indicator—Red indicates Remote has lost contact with 
Host. 
•
Remote  Lost  Fault
 status indicator—Red indicates that the Host is unable to 
communicate with the Remote. 
•
AC Power Supply Fault
 status indicator—Red indicates Remote power supply has 
failed.
•
Over Temperature Fault
 status indicator—Red indicates internal temperature in 
Remote is over its functional operating limit. Fault threshold is 
84°C
.
•
Fan Under Speed Fault
—Red indicates that the speed of the Remote fan is not 
high enough for the internal functional temperature of the Remote.
•
Under  Temperature  Fault
 status indicator—Yellow indicates that the internal 
temperature within the Remote is under the operating limit. Fault threshold is 
-40°C
.
•
Fan Over Speed Fault
—Yellow indicates that the Remote fan is not necessary for 
the current internal temperature of the Remote, but the fan is spinning (Minor 
alarm).
•
Open Door Fault
—Yellow status indicator for this Minor alarm, which indicates 
that the door to the Remote is open.
•
Apply
 button—When clicked, causes Remote Name entry to be applied
•
Refresh
 button—When clicked, causes page to be reloaded from Host
DART ID 8
RF Slot 4
DART ID 7
DART ID 6
RF Slot 3
DART ID 5
DART ID 4
RF Slot 2
DART ID 3
DART ID 2
RF Slot 1
DART ID 1
SERF Board