User's Manual
Troubleshooting Alarms
FlexWave Prism Host, Remote and EMS 5.1 System Reference Page 273
ADCP-77-073 • Issue 2 • 11/2009 © 2009 ADC Telecommunications, Inc.
fwuHstSERFOptIpEnableFault
Major An attempt to enable
IP on a fiber (Host) to
a Remote that
already has IP
enabled on another
fiber (Host) has been
made.
The alarm is cleared
if IP is disabled on
the fiber. It is also
cleared if an ACK is
later received from
the Remote. This
latter condition can
occur if the fiber that
was already carrying
IP later has IP
disabled, or if the
fiber otherwise
becomes disabled.
For information on
setting Ip Enable,
see
“Configure the
Remote SeRF Optical
Ports” on page 158
fwuRmtFanOverSpeedFault
Minor Remote fan has an
Over Speed fault
Fan may require
replacement.
fwuRmtFanUnderSpeedFault
Major Remote fan has an
Under Speed fault
Fan may require
cleaning and/or
replacement.
fwuRmtOpenDoorFault
Minor Door on the Remote
is open
Close the Remote
door
fwuHstSysCardPrimaryCPFault
Major Primary Clock
Priority Fault
Set Primary CPL
within acceptable
range
fwuHstSysCardSecondaryCPFault
Minor Secondary Clock
Priority Fault
Set Secondary CPL
within acceptable
range
Table 11-1. EMS Alarm Descriptions and Corrective Actions (Cont.)
Alarm Name Alarm
Severity
Level
Description Action