User's Manual

Managing Remote Units
Page 254 FlexWave Prism Host, Remote and EMS 5.1 System Reference
© 2009 ADC Telecommunications, Inc ADCP-77-073 Issue 211/2009
LNA Major Alarms
LNA Power Fault
—Red indicates that the Low Noise Amplifier has an internal
error.
LPA Major Alarms
LPA Disable Fault
—Red indicates that the Linear Power Amplifier is disabled
because it encountered a problem.
LPA VSWR Fault
—Red indicates that an internal VSWR fault state of the LPA.
Fault threshold is
2
.
LPA DC Fault
—Red indicates that the voltage level inside the LPA is outside
its acceptable range.
LPA Loop Fault
—Red indicates that the feedback loop inside the LPA is not
working.
LPA Over Power Fault
—Red indicates that the power level inside the LPA is
high enough to damage the LPA.
LPA Low Power Fault
—Red indicates that the internal gain of LPA does does
not meet specification.
LPA Missing Fault
—Red indicates that the LPA is missing.
DART Minor Alarms
DART Low Temperature Fault
—Yellow indicates DART temperature is too low.
Fault threshold is
-40°C
.
LPA Minor Alarms
LPA High Temperature Fault
—Yellow indicates that the LPA internal
temperature is too high.