User's Manual

Managing Remote Units
Page 242 FlexWave Prism Host, Remote and EMS 5.1 System Reference
© 2009 ADC Telecommunications, Inc ADCP-77-073 Issue 211/2009
44 If any status indicator in the
Major Alarms
or
Minor Alarms
table is red or yellow,
refer to the following list:
Remote Capacity
—Number of slots for RF Modules in the remote. Each RF
Module comprises up to two Classic DARTS or Single SuperDARTs or one Dual
SuperDART.
Remote Temperature
field—Currently detected internal temperature of the
Remote (measured near the SeRF board).
Host Lost Fault
status indicator—Red indicates Remote has lost contact with
Host.
Remote Lost Fault
status indicator—Red indicates that the Host is unable to
communicate with the Remote.
AC Power Supply Fault
status indicator—Red indicates Remote power supply has
failed.
Over Temperature Fault
status indicator—Red indicates internal temperature in
Remote is over its functional operating limit. Fault threshold is
84°C
.
Fan Under Speed Fault
—Red indicates that the speed of the Remote fan is not
high enough for the internal functional temperature of the Remote.
Under Temperature Fault
status indicator—Yellow indicates that the internal
temperature within the Remote is under the operating limit. Fault threshold is
-40°C
.
Fan Over Speed Fault
—Yellow indicates that the Remote fan is not necessary for
the current internal temperature of the Remote, but the fan is spinning (Minor
alarm).
Open Door Fault
—Yellow status indicator for this Minor alarm, which indicates
that the door to the Remote is open.
Apply
button—When clicked, causes Remote Name entry to be applied
Refresh
button—When clicked, causes page to be reloaded from Host
DART ID 8
RF Slot 4
DART ID 7
DART ID 6
RF Slot 3
DART ID 5
DART ID 4
RF Slot 2
DART ID 3
DART ID 2
RF Slot 1
DART ID 1
SERF Board