FlexWave Prism Host, Remote and EMS 5.1 System Reference Page 235
ADCP-77-073 • Issue 2 • 11/2009 © 2009 ADC Telecommunications, Inc.
10.3 CONFIGURING DUAL-SLOT LPAS
Both LPAs in a dual-slot 40W module can be controlled from the
Configuration Details
window, which allows you to set the
LPA Operating Mode
, enable/disable a LPA, or
reset a LPA, as shown below:
The following rules apply to the dual-slot LPA installation:
•• For the second LPA, the GUI displays it in an RF group by itself. There will be no
DART in the RF group. However, you will be able to view alarms and configuration
for the RF group in case of dual LPA setup. For the “missing” DART, default values
will display. You cannot configure the missing DARTs, but can set the LPA mode
and reset the LPA.
•• User-initiated configuration of dual LPAs is simulataneous for both the LPAs. If
one of the LPAs is placed into
standby
, both go into standby. If one is placed into
normal
mode, both go into
normal
mode.
•• User initiated LPA resets are simulataneous. If one LPA is reset, so is the other.
•• Alarm handling for the two LPAs occurs independently. If one alarms and goes
into
standby
, the second LPA continues in its current state. Automatic alarm
recovery is also handled independently.