User's Manual

DART Card Replacement/Installation Procedure
FlexWave Prism Host, Remote and EMS 5.1 System Reference Page 325
ADCP-77-073 Issue 211/2009 © 2009 ADC Telecommunications, Inc.
A.5 DART CARD REPLACEMENT/INSTALLATION
PROCEDURE
Each DART card is spectrum specific and provides an interface between the SeRF and
the Power Amplifier. When additional service is needed another DART card can be
added to the Host. Individual DART cards may be replaced without disrupting service
to the entire remote system. Only the RF spectrum of the DART card being removed
is affected.
A.5.1 Replacing a DART Card in the Host Chassis
11 Notify the NOC or alarm monitoring system operator that the DART card is being
replaced.
22 Disconnect REF IN and OUT cables from the front of the DART card.
33 Loosen the two thumb screws that secure the DART card to the front of the Host
enclosure.
44 Carefully withdraw the DART card from the enclosure.
55 Slide replacement DART card into the Host chassis until it is firmly seated.
66 Secure the DART card to the front of the enclosure using the two thumb screws
loosened in Step 3.
77 Connect REF IN and OUT cables to the front of the DART card.
88 Notify the NOC or alarm monitoring system operator that the system is back in
operation.
A.5.2 Installing a New DART Card in the Host Chassis
11 Notify the NOC or alarm monitoring system operator that another DART card is
being added the Host.
22 Determine slot location of the new DART card. See Figure 1-6 on Page 14 for DART
card slot assignments.
If you replace or install a DART card in the Host to change the RF, its equivalent must
be replaced o
r added to the Remote by adding or replacing the corresponding Remote
RF Module.
Electronic components can be damaged by static electrical discharge. To prevent ESD
damage, slip on a
n Electrostatic Discharge (ESD) wrist strap and connect the ground wire
to an earth ground source. We
ar the ESD wrist strap while completing each step in this
procedure.
Electronic components can be damaged by static electrical discharge. To prevent ESD
damage, slip on a
n Electrostatic Discharge (ESD) wrist strap and connect the ground wire
to an earth ground source. We
ar the ESD wrist strap while completing each step in this
procedure.