User's Manual
Power Supply Replacement Procedure
FlexWave Prism Host, Remote and EMS 5.1 System Reference Page 315
ADCP-77-073 • Issue 2 • 11/2009 © 2009 ADC Telecommunications, Inc.
A.2 POWER SUPPLY REPLACEMENT PROCEDURE
11 Notify the NOC or alarm monitoring system operator that the system will be out
of service for a period of time.
22 Turn power switch to the OFF position.
33 Unplug power plug by applying pressure to the left and right side of the connector
and pulling it straight out.
44 Loosen the two thumb screws that secure the Power Supply to the front of the
Host enclosure.
55 Carefully withdraw the Power Supply from the enclosure.
66 Slide replacement Power Supply into the Host chassis until it is firmly seated.
77 Secure the Power Supply to the front of the enclosure using the two thumb screws
loosened in Step 4.
88 Verify that the power switch is in its OFF position, and then plug power plug into
the power connector on the front of the Power Supply. Make certain that it is fully
seated.
Removing the power supply disables the Host and interrupts service.
Electronic components can be damaged by static electrical discharge. To prevent ESD
damage, slip on a
n Electrostatic Discharge (ESD) wrist strap and connect the ground wire
to an earth ground source. We
ar the ESD wrist strap while completing each step in this
procedure.
22400-A