User's Manual
Application Note 16 – version 1.1
page 9
p
plication Note
A
18) Verify the boot parameters by entering ‘bootChange’. A list of parameters appears as you press the
[ENTER] key, as shown in Figure 5.
’.’ = clear field; ’-’ = go to previous field; ^D = quit
boot device : qu
processor number : 0
host name : craftpc
file name : /home/target/vxWorks
inet on ethernet (e) : 172.16.80.42:fffff000
inet on backplane (b):
host inet (h) : 172.16.80.43
gateway inet (g) :
user (u) : target
ftp password (pw) (blank = use rsh):
flags (f) : 0xa
target name (tn) : bts
startup script (s) : /home/target/iwvstart
other (o) :
Figure 5. Verifying/Changing TurboMAX Boot Parameters
Make sure the parameters include the listed values. If so, continue with the next step. If not, reenter
‘bootChange’, press the [ENTER] key to display the desired line, press period ‘.’ to delete the
incorrect entry, type in the correct entry, and press the [ENTER] key to continue with the next
parameter. When all the bootChange parameters display the correct values, continue with the next
step.
19) Reboot the TurboMAX by pressing the [CTRL][x] key combination. Verify the current software
version and patch level by pressing [RETURN] to display the ‘bts:A->’ prompt. Then enter
‘iwversion’. The TurboMAX responds with the BSX code version, the software release, the
encryption status, and the patches currently installed. Verify that you have the software version
iw05_00.132 or later installed.
20) Verify the images loaded in the TurboMAX IWP flash version by entering ‘printConfigBlocks’. The
resulting parameters display the Primary Config Block imageCurrent and Secondary Config Block
imageCurrent entries in the form ‘iwXX_YY.ZZZ’, which indicates the IWP flash version. Contact
Technical Support to ensure you have IWP flash version iw05_00.132 or later installed.
21) Run the E1 or T1 POST diagnostics by disconnecting all E1 and T1 lines from the TurboMAX,
entering ‘reboot’ at the ‘bts:A->’ prompt. Verify that the resulting seven sequential tests appear as
‘PASSED’. If the E1 or T1 Trunk card fails any of these tests, the E1 or T1 card is defective; return
the E1 or T1 card to interWAVE, and redo this test with the replacement E1 or T1 Trunk card.
22) Terminate any existing telnet and/or rlogin session by logging in as root (bts:A-> su – root), clearing
existing sessions (# /sbin/arp –d iwbox), and logging out of root (# exit).