User's Manual

Application Note 16 version 1.1
page 8
p
plication Note
A
IW206001
ON/LINE
PORT 1
12
PORT 0
12
ALARMS
FLT
PWR
ALARMS
Craft PC
computer
IWP, 64MEG, MMU
HARD DISK
DB-9 port
connector
DB-9 extension cable
DB-9 port
connector
ON
LINE
PWR
FLT
SCN
RST
CON
ENET
EXT
XREF
Figure 4. Connecting the Craft PC to the TurboMAX via the Serial Port
15) Power up the Craft PC, and allow the Linux operating system to bootup.
16) Logon as build, and start XWindows by entering startx.
17) Establish serial communications with the TurboMAX by entering cu l ttyS0 s 9600. The