Installation Manual

Table Of Contents
Release 3.3, Revision A 1/99
Off-Line Commissioning 73
Locate the line labeled
Image Current
in the primary and secondary config block which are highlighted above. These
lines have the format:
iwxx_yy.zzz
where iwxx_yy.zzz indicates the IWP flash version.
The flash version number should be 01_00.101 or higher for WAVEXpress/BTS TRX POST diagnostics to be able to
run. If it is not, the flash version number will have to be changed and the BTS rebooted. To do this, refer to Chapter 8,
BTS Management, located in the Craft PC Guide.
PR I M A R Y C O N F I G B L O C K:
1 (t3)idString :PrimarYFlasHConfiGSectoR
2 (t3) version :3
3 (t3) sequenceNumber :2
4 (t3) imageCRC :0xa18h (valid)
5 (t3) imageLength :440
6 (t3) creationTime :THU JAN 01 00:00:16 1970
7 (t3) imageCurrent :image A (0x80000) iw03_00.101
8 (t3) imagePrevious :image B (0x140000) iw03_00.101
9 (t3) imageA startup file: none
10 (t3) imageB startup file:none
11 (t3) Abis signalling chno:0
12 (t3) bootLine :qu(0,0)craftpc:/home/target/vxWorks
e=172.16.80.42
13 (t3) :fffff000 h=172.16.80.43 u=target f=0xa tn=bts s=/
14 (t3) home/target/bsxstart
15 (t3)
16 (t3) S E C O N D A R Y C O N F I G B L O C K:
17 (t3)idString :SecondarYFlasHConfiGSectoR
18 (t3)version :3
19 (t3)sequenceNumber :2
20 (t3)imageCRC :0xa18h (valid)
21 (t3) imageLength :440
22 (t3) creationTime :THU JAN 01 00:00:16 1970
23 (t3)imageCurrent :image A (0x80000) iw03_00.101
24 (t3)imagePrevious :image B (0x140000) iw03_00.101
25 (t3) Abis signalling chno:0
26 (t3) imageA startup file:none
27 (t3) imageB startup file:none
28 (t3)bootLine :qu(0,0)craftpc:/home/target/vxWorks
e=172.16.80.42
29 (t3) :fffff000 h=172.16.80.43 u=target f=0xa tn=bts s=1
30 (t3) home/target/bsxstart
Figure 4-5:
Determining the IWP flash version