Installation Manual
Table Of Contents
- WAVEXpress/BTS Installation and Commissioning Guide
- One - Unpacking the WAVEXpress/BTS
- Two - Internal BTS Cabling and Jumpering
- Three - Installation
- 3-1 Wall Installation
- 3-2 Table Mount
- 3-3 Rack Installation
- 3-4 Common Final Installation Procedures
- 3-4.1 Connection of the Cable Gland
- 3-4.2 Connection of the Grounding Cable
- 3-4.3 Connection of the Antennas to the Bulkhead Plate
- 3-4.4 Connection of the Optional Combiner Assembly
- 3-4.5 Connection of the Power Supply
- 3-4.6 Connection of the T1 Lines
- 3-4.7 Connection to External Alarms
- 3-4.8 Optional Voltage Standing Wave Ratio (VSWR) Check
- 3-4.9 Post Installation Checks
- 3-5 Outdoor Installation
- Four - Off-Line Commissioning
- Five - Off-Line Commissioning of a Daisy Chain
- Six - Post Off-Line Commissioning
- Seven - On-Line Commissioning
- Appendix 1 - Connection of the Combiner Assembly
- Appendix 2 - BTS Field Maintenance
- A2-1 WAVEXpress/BTS Field Replacement Maintenance
- A2-1.1 Replacing the WAVEXpress/BTS IWP card
- A2-1.2 Replacing the WAVEXpress/BTS T1 card
- A2-1.3 Replacing the WAVEXpress/BTS TRX card
- A2-1.4 Replacing the WAVEXpress/BTS RF distribution card
- A2-1.5 Replacing the clock module
- A2-1.6 Replacing power supply units
- A2-1.7 Replacing fan assemblies
- A2-1.8 Replacing filters (p/n 520081-01)
- A2-1.9 Replacing the antenna bracket with a combiner assembly
- A2-1 WAVEXpress/BTS Field Replacement Maintenance
- Checklist 1 - Installation Checklist
- Checklist 2 - Commissioning Checklist
Release 3.3, Revision A 1/99
Off-Line Commissioning 71
Step 3
For the new parameters to take effect, reboot the WAVEXpress/BTS by pressing the key combination
[CTRL][x].
Table 4-2: Changing Boot Parameters
Command Action
[ENTER]
Accepts the current parameter value and proceeds to the next parameter.
.
[ENTER]
Erases the current parameter value and proceeds to the next parameter.
-
[ENTER]
Returns to the previous parameter.
[CTRL][D]
Aborts all changes to the boot parameter and revert to the current value.
Figure 4-4:
Verifying/changing WAVEXpress/BTS boot parameters
NOTE
☛
You must edit the boot parameters to contain the EXACT values shown in bold in the
above display, or the WAVEXpress will not bootup properly.
'.' = clear field; '-' = go to previous field; ^D =
quit
boot device :
qu
processor number :
0
host name :
craftpc
file name :
/home/target/vxWorks
inet on ethernet (e) :
172.16.80.42:fffff000
inet on backplane (b):
host inet (h) :
172.16.80.43
gateway inet (g) :
user (u) :
target
ftp password (pw) (blank = use rsh):
flags (f) :
0xa
target name (tn) :
bts
startup script (s) :
/home/target/bsxstart
other (o) :