Installation Manual

Table Of Contents
Release 3.3, Revision A 1/99
22 WAVEXpress/BTS Installation and Commissioning Guide
2-2.3 Cable Connection for a 2 TRX WAVEXpress/BTS system
Check the following cables in addition to those already checked for a 1 TRX WAVEXpress/BTS system:
Step 1
Locate the receive cable labeled with the descriptor Rx slot 4,5 and part number 740045.
Step 2
Ensure that one end of this cable is connected to the port labeled Rx 4,5 on the RF Dist card, and the
other end is connected to the Rx port on the TRX card located in slots 4 and 5 of the chassis.
Step 3
Locate the transmit cable labeled with the descriptor Tx slot 4,5 and part number 740046.
Step 4
Ensure that this cable is connected to one end to the port labeled Tx 4,5 on the RF Dist card, and the
other end is connected to the Tx port on the TRX card located in slots 4 and 5 of the chassis.
Step 5
Using a SMA torque wrench, check that the SMA connectors on either end of the cables are tightened to
7-10 in/lbs. (80-115 N cm).