Installation Manual

Table Of Contents
Release 3.3, Revision A 1/99
10 WAVEXpress/BTS Installation and Commissioning Guide
The impedance level of the card may be chosen by configuring the DIP switch according Figure 1-7 which provides
the T1 DIP switch settings for both Port A and Port B given the length of a shielded twisted pair cable. Refer to Figure
1-5 for T1 DIP switch location and pin identification.
NOTE
The T1 card DIP switch is set according to DSX cable length or line build out. The
proper DIP switch settings should be identified during the initial system installation .
Table 1-7:
T1 dip switch settings
Port A
Switch Setting
1-2-3-4
Port B
Switch Setting
5-6-7-8
DSX-1 Cable Distance
Feet (Meters)
CSU Line
Build-Out
O-C-C-C O-C-C-C 0-133 (0- N/A
O-O-C-C O-O-C-C 133-266 N/A
O-C-O-C O-C-O-C 266-399 N/A
O-O-O-C O-O-O-C 399-533 N/A
O-C-C-O O-C-C-O 533-655 N/A
O-O-C-O O-O-C-O N/A 0dB
O-C-O-O O-C-O-O N/A -7.5dB
O-O-O-O O-O-O-O N/A -15dB
C-O-X-X C-O-X-X N/A -22.5dB
O = Open, C = Closed, X = Either