8 WAVEXpress/BTS Installation and Commissioning Guide
1-3.4 interWAVE Processor (IWP) Card
The following table describes the function of the connectors and indicators on a
WAVEXpress/BTS IWP card. Refer to the illustration on the left for the position of connectors
and indicators.
Table 1-4:
WAVEXpress/BTS IWP card’s connectors and indicators
Connector or
Indicator
Function
RST This button resets the card.
SCN When lit, the system controller LED indicates the IWP is
operational.
PWR Green LED, lit when card has power supplied.
ONLINE Green LED, lit when card is on-line, downloaded, and
card boot process has been performed successfully.
FLT Red LED, lit when the card detects a fault or the card has
not downloaded successfully.
CON 9-pin, RS232 connector for serial connection to the Craft
PC.
ENET 15-pin, DB-15 connector for Ethernet connection to the
Craft PC.
EXT RJ45 for external alarm connection.
XREF SMA connector for input from external clock for system
synchronization.
NOTE
A BTS 16Mb IWP card has the part number 340123. This part numbers is visible
on the front face of the IWP card.
ON
LINE
PWR
FLT
SCN
RST
CDN
ENET
EXT
XREF
IW352802
IWP, 16MEG, MMU