User's Manual Part 2
SCP-LPS20x-011-012-01H December 20, 2004
166 ADC Telecommunications, Inc.
SETTING PARAMETERS
Filter
Specify the type of messages that will be recorded in the log. Each message level includes all those below it. For
example, if you select “notice,” then all messages under it in the list are included. This means that selecting “debugs”
logs all messages. Messages are classified as follows:
• Debug: Debug-level messages
• Info: Informational messages
• Notice: Normal, but significant condition
• Warning: Warning condition
• Error: Error condition
• Critical: Critical condition
• Alert: Action must be taken immediately
• Emergency: System is unusable
Syslog Server
Specify the address of the device to send log entries to.
Syslog Server Facility
The facility that will be used when logging messages to a syslog server. Available facilities are local0-local7.